INSPECTION

We conduct a thorough inspection of your commercial kitchen air exhaust system for cleanliness in accordance with NFPA 96 and the Quebec Construction Code.

 

CLEANING

If grease deposits are found during the inspection, the commercial kitchen air exhaust system must be cleaned.

The inspection certificate of the commercial kitchen air exhaust system required by the law and many insurance companies must be posted on the premises by the owner; it indicates the inspection and cleaning date, inaccessible locations and the name of the certified company that performed the work.

Cadexair is an active member of the professional association IKECA. This organization ensures that the work of its members is carried out in strict compliance with Canadian codes and standards.

 

FILTER ROTATION

Our factory is equipped with a cleaning room specialized for hood filters.

Here are some advantages of a regular filter rotation:

  • Facilitates hood maintenance
  • Minimal disruption of your kitchen operations
  • Optimizes the exhaust performance of your hood
  • Clean appearance for hoods in your customer area

 

FREE ONLINE CUSTOMER ACCESS

Cadexair offers a free secured online access to all important documentation:

  • Contracts
  • Work orders
  • Pictures before & after cleaning
  • Certificates
  • Simdut datasheets for all cleaning products
 

STANDARDS AND REGULATION

The Quebec Construction Code refers to NFPA96 2004 to regulate the construction and maintenance of commercial kitchen ventilation systems.

The authorities having jurisdiction, including the fire protection services and insurers, have a mandate to reinforce the application of this standard.

 

ARTICLES CONCERNING THE MAINTENANCE OF VENTILATION SYSTEMS

11.3 Inspection for Grease Buildup. The entire exhaust system shall be inspected for grease buildup by a properly trained, qualified, and certified company or person (s) acceptable to the authority having jurisdiction in accordance with table 11.3.*

11.4.1 Upon inspection, if found to be contaminated with deposits from grease-laden vapors, the contaminated portions of the exhaust system shall be cleaned by a properly trained, qualified, and certified company or person (s) acceptable to the authority having jurisdiction.

* For more information on this table, contact us.

 

IKECA CERTIFICATION

Cadexair is proud to be an active member of IKECA for more than 10 years! Founded in 1989, IKECA is an international non-profit organization dedicated to fire prevention and safety by developing and promoting the highest standards in the industry.

The new ANSI/IKECA C-10 standard published in 2011 is the result.Each member must have at least a competency card through examinations, follow continuing education and meet the highest quality standards. For more information, visit www.ikeca.org.


 Cadexair employees are investigated and authorized to work in Canada's secured establishments